The power of MRI, redesigned
Compact MRI for the Research Lab and the NICU.
Self-shielded, permanent-magnet MRI that can be placed in almost any location, without the infrastructure requirements of superconducting systems. The M-Series for preclinical research. Embrace® for neuroimaging inside the NICU.
- 1.0 TM-Series magnet field
- Up to 700 grats imaged in the M7
- One dayto install an M5 or M7

Preclinical imaging
Three Magnet Sizes, One Way of Working
Each M-Series™ system pairs a compact 1.0 T permanent magnet on a portable cart with the same workstation, software and electronics, so moving up a size is a magnet-only upgrade.

For mice
M3
A bore size optimized for mice, for high-resolution 3D anatomical, functional and molecular images.
- Field
- 1.0 T
- Imaging volume
- 80 × 80 × 35 mm spheroid
- Magnet and stand
- 1080 × 734 × 734 mm
M3 details (opens in a new tab)Spec sheet for the M3 (PDF, opens in a new tab)

For mice and rats
M5
A larger bore opening for dedicated imaging of both mice and rats, and ex vivo samples.
- Field
- 1.0 T
- Imaging volume
- 90 × 90 × 60 mm spheroid
- Magnet and stand
- 1133 × 800 × 800 mm
M5 details (opens in a new tab)Spec sheet for the M5 (PDF, opens in a new tab)

For small mice to large rats
M7
Imaging of mice and rats weighing up to 700 grams: 2D and 3D, ex vivo, in vivo and in vitro.
- Field
- 1.0 T
- Imaging volume
- 120 × 120 × 70 mm spheroid
- Magnet and stand
- 1320 × 790 × 950 mm
M7 details (opens in a new tab)Spec sheet for the M7 (PDF, opens in a new tab)

Simultaneous PET/MRI
SimPET
An MRI-compatible SiPM PET insert for truly simultaneous PET/MRI studies in small animals, with a 2-year standard warranty.
- Pairs with
- M7
- Operation
- Simultaneous or standalone
- Attenuation correction
- MRI-based
SimPET details (opens in a new tab)Spec sheet for the SimPET (PDF, opens in a new tab)
Specifications from Aspect Imaging’s M-Series spec sheets. Aspect Imaging offers the SimPET insert with Brightonix Imaging.
Size it to the room
See the Footprint Before You Plan the Space
Choose a system to draw its magnet and stand to scale on a floor grid of 250 mm squares, beside the electronics cabinet every M-Series system shares.
- Magnet and stand
- 1133 × 800 × 800 mm
- Weight
- 950 kg
- Imaging
- Mice and rats
- Bore
- 76 × 200 mm inner bore, open
- Imaging volume
- 90 × 90 × 60 mm spheroid
Every M-Series system needs no
- RF shielding
- Dedicated housing facilities
- Dedicated power supply
- Compressor, pumps or special plumbing
- Cryogens
Your choice, M5, goes into the form.
One instrument, many applications
Quantify Phenotypes, Again and Again
The systems are designed to quantify phenotypes routinely and repeatedly in models of disease, in vivo and ex vivo. These are images from Aspect Imaging’s own applications pages.

Anatomy and MorphologyIn vivo soft tissue imaging for morphological characterization. 
Cancer ResearchDetection, follow-up and quantification of tumor development and progression. 
NeurobiologyIn vivo anatomical imaging of the brain, spine and spinal cord. 
Multi-modality ImagingEasy registration with optical, PET, SPECT and CT for multi-modality phenotyping. 
Ex Vivo Imaging3D MR-based histology of fixed samples and embryos. 
Simultaneous PET/MRIMR, PET/MR and PET images from the SimPET page gallery.
Research areas
- Cancer
- Cardiovascular
- Contrast-based molecular imaging
- Diabetes and obesity
- Embryology and developmental biology
- Nephrology
- Neurobiology
- Stem cell and cell tracking
Customer testimonials
In Researchers’ Own Words
My field of research is nanomedicine and nanomaterials for cancer theranostics. I have used Aspect Imaging’s Compact MRI system for 6 years and I am very satisfied with the system’s quality and reliability. It is extremely simple to use and robust, providing reliable and accurate results which I have published in many peer-reviewed journals.
The USC Molecular Imaging Center (MIC) has recently added the Aspect MRI for preclinical imaging services. It is extremely robust and user friendly. It perfectly complements our other molecular imaging modalities at the center.
Clinical imaging
Neuroimaging Without Leaving the NICU
“The Embrace® Neonatal MRI System from Aspect Imaging is the first FDA-cleared MRI system, designed specifically for use on critically-ill babies inside the NICU.”
- Smaller footprint promotes ease of placement inside the NICU
- Thermo-controlled patient bed keeps the baby warm and comfortable throughout the scanning process
- Unique self-shielded magnet design enables equipment, staff and parents to remain close by
- Off-unit patient transport is eliminated, creating a more simplified workflow and saving valuable time
System features: quiet operation; no cryogens; no cooling system, backup electrical supply, special room or zone 4 safety room required.
Frost & Sullivan recognized Aspect Imaging Ltd. with the 2020 Global Technology Innovation Leadership Award, for the Embrace Neonatal MRI System.

Service and support
From First Call to First Scan
An experienced team of engineers and scientists offers maintenance, repair, technical support and training, when and where it is needed, to help minimize downtime.

Speak With a Specialist
Tell us what you image and where. A specialist helps you choose the M-Series system that is right for your research.
See It in a Virtual Demo
Watch the system, the workstation and the imaging workflow in a demo scheduled with our team.
Wheel It Into Place
The magnet sits on a portable cart. The M5 and M7 pages list a one-day installation, with no shielded room to build first.
Train, Scan and Stay Supported
System training, technical support and service plans keep the system performing. Support is one email away at support@aspectimaging.com.
About Aspect Imaging
Breakthrough Magnets, Simpler MRI
Aspect Imaging Ltd designs and develops compact MR imaging systems for preclinical and medical applications. Its compact, high-performance permanent magnets are the backbone of every product, built so scientists, researchers and medical professionals can harness the power of MRI without the complexity and cost of conventional imaging systems.
Answers
Questions Researchers Ask
Does an M-Series system need a shielded room?
No. The permanent magnet design requires no RF shielding, no dedicated housing facilities, no dedicated power supply and no compressor, pumps or special plumbing. The systems are cryogen-free.
Which system suits rats?
The M3 has a bore optimized for mice. The M5 has a larger bore opening for dedicated imaging of both mice and rats. The M7 images small mice to large rats weighing up to 700 grams.
Do our researchers need MR experience?
The M3, M5 and M7 pages say that biologists and researchers without prior MR or imaging experience can now use MRI for morphological imaging, and the M-Series brochure says its intuitive software interface and analysis tools require no prior experience in MR imaging. System training is part of service and support.
Can a system sit behind the bio-containment barrier?
Yes. The small footprint and lightweight design of the M3, M5 and M7 allow flexible placement where it is needed most, even behind the bio-containment barrier for in vivo imaging.
Can we add PET to our MRI studies?
SimPET, offered with Brightonix Imaging, is an MRI-compatible PET insert for truly simultaneous PET/MRI studies in small animals with the M7. The M3 and M5 spec sheets describe pairing with Brightonix Imaging’s preclinical PET system for sequential PET/MRI studies.
How long does installation take?
The M5 and M7 pages list a one-day installation. The magnet sits on a portable cart and is wheeled into position, with no shielded room to build first.
Where can I learn more about the Embrace Neonatal MRI System?
Embrace has its own website, embracemri.com (opens in a new tab), with its benefits, image gallery, case studies and webinars. You can also ask about it with the form below.
How do we reach technical support?
Email support@aspectimaging.com. Aspect Imaging offers technical support, system training and service plans.
Contact
Let’s start a conversation.
For product information, sales, service and support, complete the form and a member of the Aspect Imaging team will be in touch.
- Sales and product informationinfo@aspectimaging.com
- Technical supportsupport@aspectimaging.com
- Embrace Neonatal MRIembracemri.com (opens in a new tab)